BNQJM - MD-4L, COPYMIX FOR MINOLTA ELECTROGRAPHIC 1

  • MSDS: BNQJM
  • Manufacturer: HILORD CHEMICAL CORP
  • Product Name: MD-4L, COPYMIX FOR MINOLTA ELECTROGRAPHIC 1
  • National Stock Number: 6850-00N020163
Product Identification

Product ID:MD-4L, COPYMIX FOR MINOLTA ELECTROGRAPHIC 1
MSDS Date:04/03/1991
FSC:6850
NIIN:00N020163
MSDS Number: BNQJM

Responsible Party
HILORD CHEMICAL CORP
70 ENGINEERS RD
HAUPPAUGE, NY 11788-4004
US

Emergency Phone: 516-234-7373

Info Phone: 516-234-7373

Cage: 1EV20

Contractor
HILORD CHEMICAL CORP
HAUPPAUGE, NY 11788-4004 US

Telephone: 516-234-7373

Cage: 1EV20

Ingredients

ALL OTHER CONTRS SHLD BE DISPOSED OF IN

RTECS: 9999999ZZ


EFTS IN MALE RATS. PROD HAS LOW ORDER OF

RTECS: 9999999ZZ


INTO LUNGS DURING INGEST MAY CAUSE MILD TO SEVERE

RTECS: 9999999ZZ


DIKING/IMPOUNDING. ADVISE AUTH IF PROD HAS

RTECS: 9999999ZZ


AREAS. ASSURE CONFORMITY W/APPLIC GOVERN REGS.

RTECS: 9999999ZZ


ABSORBED MATL. FOR FURTHER INFO RELATIVE TO SPILLS

RTECS: 9999999ZZ


DOT EMERGENCY RESPONSE GUIDEBOOK FOR HAZ MATLS

RTECS: 9999999ZZ


USE EXPLOSION-PROOF EQUIPMENT.

RTECS: 9999999ZZ


AT END OF WORK PERIOD. PROD IS READILY

RTECS: 9999999ZZ


WASHING THOROUGHLY WITH SOAP AND WATER.

RTECS: 9999999ZZ


HYDROTREATED HEAVY NAPHTHA (PETROLEUM); (ISOPAR, CONSISTS

CAS: 64742-48-9

Fraction By Weight: 99.74%


EMPTY DRUMS SHLD BE COMPLETELY DRAINED/PROPERLY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL, RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HLTH STUDIES HAVE SHOWN THAT MANY
PETROLEUM HYDROCARBONS & SYNTH LUBRICANTS POSE POTNTL HUMAN HLTH
RISKS WHICH MAY VARY FROM PERSON TO PERSON. AS A PREC, EXPOS TO
LIQ/VAPS/MISTS/FUMES SHLD BE MINIMIZE D. HIGH VAP CONC (>APPROX
100PPM) ARE IRRIT TO EYES/RESP TRACT, MAY CAUSE HDACH/DIZZ, ARE
ANESTHETIC, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: AND MAY HAVE OTHER CNS EFTS.
PRLNG/RPTD SKIN CONT W/PROD TENDS TO REMOVE SKIN OILS POSSIBLY
LEADING TO IRRIT/DERMAT. MAY CAUSE EYE IRRITATION. LAB ANIMAL
STUDIES HAVE SHOWN THAT PRLNG/RPTD I NHAL EXPOS TO LIGHT HYDROCARB
VAPS IN THE SAME NAPHTHA BOILING RANGE AS THIS PROD CAN PRDCE
ADVERSE KIDNEY (ING 4)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/CLEAR WATER FOR A MINIMUM OF 15 MIN OR UNTIL
IRRIT SUBSIDES. IF IRRIT PERSISTS, CALL MD. SKIN: REMOVE ANY
CONTAMD CLTHG & WASH SKIN THOROUGHLY W/SOAP & WATER. INHAL: REMOVE
FROM EXPOS & CALL MD IMMED. IF BRTHG IS IRREGULAR ORHAS STOPPED,
START RESUSCITATION, ADMINISTER OXYGEN, IF AVAIL. INGEST: DO NOT
INDUCE VOMITING; CALL MD IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:100F,38C
Lower Limits:0.8%
Upper Limits:7%
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEMICAL, C*O2 &
VAPORIZING LIQUID TYPE EXTINGUISHING AGENTS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER MAY BE INEFTIVE, BUT SHLD BE USED TO KEEP FIRE-EXPOSED
CONTRS COOL. IF LEAK/SPILL HAS (SUPP DATA)
Unusual Fire/Explosion Hazard:EMPTY CONTRS RETAIN RESIDUE (LIQ/VAP) &
CAN BE DANGEROUS. DO NOT PRESSURIZE/CUT/WELD/
BRAZE/SOLDER/DRILL/GRIND OR EXPOSE SUCH CONTRS TO HEAT/FLAME (SUPP
DATA)

Accidental Release

Spill Release Procedures:SHUT OFF & ELIM ALL IGNIT SOURCES. KEEP PEOPLE
AWAY. RECOVER FREE PROD. ADD SAND/EARTH/OTHER SUITABLE ABSORB TO
SPILL AREA. MINIMIZE BRTHG VAPS/SKIN CONT. VENT CONFINED SPACES.
OPEN ALL WINDOWS/DOORS. KEEP PROD OUT OF SEWERS/ WATERCOURSES BY
(ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP PROD AWAY FROM HEAT/SPARKS/PILOT
LIGHTS/ STATIC ELECTRICITY/OPEN FLAME. KEEP CONTRS/STORAGE CONTRS
CLOSED WHEN NOT IN USE.
Other Precautions:DO NOT STORE NEAR HEAT/SPARKS/FLAME OR STRONG
OXIDANTS. TO PVNT FIRE/EXPLOS RISK FROM STATIC ACCUM/DISCHARGE,
EFTIVELY GROUND PROD TRANSFER SYS I/A/W NFPA STD FOR PETROLEUM
PRODS. MINIMIZE BRTHG OF VA PS. AVOID PRLNG/RPTD CONT W/SKIN.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED SUPPLIED-AIR RESPIRATORY
PROTECTION IN CONFINED OR ENCLOSED SPACES, IF NEEDED.
Ventilation:USE ONLY W/VENT SUFFICIENT TO PVNT EXCEEDING RECOMMENDED
EXPOSURE LIMIT/BUILDUP OF EXPLOSIVE CONC OF VAP IN AIR.(ING 10)
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL-RESISTANT APRON/OTHER IMPERVIOUS
CLTHG TO AVOID CONTAM REGULAR CLTHG WHICH COULD RSLT IN PRLNG/RPTD
SKIN CONT.
Work Hygienic Practices:LAUNDER & DRY-CLEAN CONTAMD CLTHG/SHOES BEFORE
REUSE. CLEANSE SKIN THORO AFTER CONT, BEFORE BREAKS/MEALS, AND (ING
11)
Supplemental Safety and Health
FIRE FIGHT PROC: IGNITED, USE WATER SPRAY TO DISPERSE VAPS & TO PROT
MEN ATTEMPTING TO STOP A LEAK. WATER SPRAY MAY BE USED TO FLUSH
SPILLS AWAY FROM EXPOS. EXPLO HAZ: SPARKS OR OTHER SOURCES OF IGNIT
; THEY MAY EXPLODE & CAUSE INJURY/DEATH. DO NOT ATTEMPT TO CLEAN
SINCE RESIDUE IS DFCLT TO REMOVE. (ING 2)

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:>311F,>155C
Melt/Freeze Pt:M.P/F.P Text:<0F,<-18C
Vapor Pres:<10 @ 25C
Vapor Density:5
Spec Gravity:0.75
pH:NEUT
Evaporation Rate & Reference:0.3(BUAC=1)@1 ATM AND 25C
Solubility in Water:NEGLIGIBLE; <0.1%
Appearance and Odor:BLACK LIQUID, FAINT PETROLEUM HYDROCARBON ODOR.
Percent Volatiles by Volume:99.74

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/STRONG OXIDANTS SUCH AS LIQUID CHLORINE, CONCENTRATED
OXYGEN, SODIUM HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:UNDER FIRE CNDTNS: FUMES, SMOKE,
CARBON MONOXIDE, ALDEHYDES & OTHER DECOMP PRODS, IN THE CASE OF
INCOMPLETE COMBUSTION.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE, AND LOCAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.